Cabinet Thermal Map Sensor

Monitor Temperature Differential (∆T) Across Your IT Rack
Essential Input for sensorCFD AI
Cabinet Thermal Map Sensor

Detect Hotspots and Coldspots in your Data Center

Cabinet Thermal Map Sensors identify and eliminate hotspots in your cabinets.

The Rack Thermal Map Sensor consist of a string of 3x temperature sensors and 1x humidity sensor. Placed at the top, middle and bottom of the rack. Two strings are combined on a single sensor port, front and rear of the cabinet. Cabinet Thermal Map Sensors monitor the air intake and exhaust temperatures of your cabinet, as well as the ∆T of the rack. Use thermal map sensors to identify cabinet hot spots that can endanger your uptime.

The sensor is an essential input to the sensorCFD AI feature in Quicklime DCIM. With sensorCFD you create almost real-time Computational Fluid Dynamics Model of your data center. With our AI analytical tools you don’t only identify where you have a problem, but what the underlying issues are and suggestions on how to fix them.

Thermal Map Sensor Infographic

Thermal map sensors identify coldspots in your data center, eliminating cold spots frees stranded capacity and saves energy.

Are there areas of your data center that are over cooled? Over cooling wastes energy. Identifying and eliminating cold spots can increase data center energy efficiency and lower operational costs. Release stranded capacity, increasing server loads in cold spots allows increased compute power without any increase in cooling capacity.

Thermal map sensors connect to AKCP sensorProbe+ base units. Extendable up to a maximum of 18 meters cable length. Up to 16 thermal maps can be connected to a single SPX+, or deploy the SP1+ on each rack.

The sensor splitter box allows 2 strings to be connected to a single sensor port, and combined with the contactless current meter to give thermal mapping and power monitoring for each rack. This is required for AKCP sensorCFD™ calculations.

AKCP Data Center Monitoring

Build a complete rack monitoring system connecting AKCP sensors to your SP1+. Fully SNMP compliant, monitor from your existing NMS or using our Quicklime DCIM.

Dual Temperature
Measurement Range -40°C to +75°C
-40°F to +167°F
Measurement Resolution 0.1°C increments
0.2°F increments
Measurement Accuracy Maximum ±0.3 at -40ºC, minimum ±0.3 at +25ºC to +75ºC
Maximum ±0.6 at -40ºF, minimum ±0.6 at +77ºF and to +167ºF
Dual Humidity
Measurement range-0 to 100% Relative humidity
Measurement Resolution1%RH increments, 0.01%RH sensor reading
Measurement AccuracyAt 25°C
Min : ±2%RH
Max : ±5% RH
Interface
Communication CableRJ45 jack to sensor using UTP CAT5e/6
Power SourcePowered by the sensorProbe+ family units. No additional power needed.
Power ConsumptionTypical 75 mWatt, 15 mA
Maximum Cable LengthSensor canbe extended from the RJ-45 Intelligent Sensor ports on the Base units up to 60 feet, or 18 meters using standard CAT5-6 LAN cable
 sensorProbe+ units auto detects the presence of the Cabinet Thermal Map Sensor
Dimension75 x 55 x 27 mm
MountingVHB Tape, Magnetic (optional)
ComponentsManufactured using highly integrated, low power surface mount technology to ensure long term realibility.
Operation EnvironmentTemperature: Min. -35°C – Max. 80°C
Humidity: Min.20% – Max. 80% (Non-Condensing)
Sensor countTHMS-V2: 4
CTHMS-V2: 11
CTHMSV2 tech drawing